Agilis Compact 250W-300W-400W C-BAND BUC ، Alb190/290 Series

  • Engineered with cutting-edge thermal efficiency, this BUC delivers outstanding power performance and reliability, even in the most demanding outdoor conditions.
  • Its advanced thermal design ensures superior energy efficiency, making it one of the most dependable and robust units in its class.
  • Featuring a straightforward and integrated 1+1 redundancy configuration, it allows for seamless failover without the need for external controllers—ensuring uninterrupted operation with minimal setup effort.

Key Features

  • Real-time detection of forward, reflected, and input power levels

  • Dedicated port for output power monitoring

  • Flexible Monitoring & Control via Serial and Ethernet interface options

  • Intelligent fault detection with automatic alarm notifications

  • LED indicators for clear visual status and alarm alerts

  • Automatic gain control maintains performance across full temperature range

  • Integrated 1+1 redundancy support—no external controller required

  • Built-in harmonic filter ensures signal purity

  • Wide operating temperature range: -40°C to +60°C

  • IP65-rated weatherproof enclosure for outdoor reliability

  • Fully RoHS compliant for environmentally responsible design

 

RF Specifications

Category Parameter Specification
Frequency Band Band Transmit (MHz)
Intelsat C 5850 – 6425
Full C 5850 – 6725
Spe. Gorizont C 5725 – 6525

Output Power

Power Rating Psat P1dB Plinear
250W 54.0 dBm (250W) – 51.0 dBm (126W)
300W 54.8 dBm (300W) – 51.0 dBm (126W)
400W 56.0 dBm (400W) – 52.2 dBm (166W)

Gain and Signal Characteristics

Parameter Specification
Small Signal Gain 75 dB min (250W), 78 dB min (300~400W)
Gain Flatness ±2 dB across full band, ±1 dB over 40MHz
Gain Variation ±1.5 dB over temperature range
Intermodulation -25 dBc max @ Plinear
Spurious Compliant with EN 301 443
Phase Noise -100 dBc/Hz max @ 100 kHz offset
-90 dBc/Hz max @ 10 kHz offset
-80 dBc/Hz max @ 1 kHz offset
VSWR 1.5:1 max (input & output)
Noise Power Density Tx Band: -70 dBW/4kHz max
Rx Band: -142 dBW/4kHz max

Power Specifications

Parameter Specification
Prime Power 190 – 264 Vac, 47 – 63 Hz
Power Consumption 1500 VA typical @ 250W
2000 VA typical @ 400W

Interfaces

Interface Specification
IF Input N-Type Female, 50Ω
RF Output WR137 Grooved Waveguide

Reference Signal

Parameter Specification
Source Internal/External Auto-Sensing
Frequency 10 MHz
Ext. Ref. Power Level -5 dBm to +5 dBm
Ext. Ref. Phase Noise -160 dBc/Hz @ 100 kHz offset
-155 dBc/Hz @ 10 kHz offset
-150 dBc/Hz @ 1 kHz offset

 

Monitor & Control Specifications

Function Description
BUC Temperature Monitoring Real-time temperature status
Status Alarm LED indicator for alarms and operational status
LO Unlock Alarm Alerts if local oscillator fails to lock
Power Detection RF Input, Forward, and Reflected Power Monitoring
Gain Control Adjustable gain up to 30 dB in 0.5 dB steps
RF Output Control RF Output On/Mute selectable
Communication Interfaces Serial RS232 / RS485
Ethernet (SNMP & HTTP)
Transmit Redundancy Built-in 1+1 redundancy system – no external controller needed

Environmental Specifications

Parameter Specification
Operating Temperature -40°C to +60°C
Relative Humidity Up to 100%
Weather Protection IP65-rated weatherproof housing

Mechanical Specifications

Parameter Specification
Dimensions (excluding connectors) 535 mm (L) × 300 mm (W) × 168 mm (H)
21.06 in × 11.81 in × 6.61 in