The cable run between your VSAT outdoor unit and your modem is called the IFL — Intermediate Frequency Link. It carries the satellite signal after the LNB has downconverted it from Ku or C-band to L-band (950–2150 MHz), and it carries the uplink signal from your BUC before transmission.
Get the IFL cable wrong — wrong type, wrong length, connectors not properly terminated — and your link budget suffers before a single packet reaches the satellite. This guide covers what the IFL is, how to choose the right cable, how to calculate loss for your specific run, and what maximum lengths apply to each cable type.
What Is an IFL Cable?
IFL stands for Intermediate Frequency Link. It is the coaxial cable connecting two points in a VSAT system:
BUC + LNB
L-band 950–2150 MHz
+ DC power + DiSEqC
VSAT Modem
The LNB downconverts the received satellite signal from Ku-band (10.7–12.75 GHz) or C-band (3.7–4.2 GHz) to L-band (950–2150 MHz). The BUC upconverts the transmit signal from L-band to Ku or C-band. The IFL cable carries both of these L-band signals simultaneously — receive down, transmit up — through a single coax run. The IFL also carries DC power from the modem to the LNB and, in most systems, carries the DiSEqC or tone commands that control LNB polarisation and band switching.
IFL Cable Specifications
Frequency Range
The IFL operates at L-band: 950 MHz to 2,150 MHz for most Ku-band VSAT systems.
| System Type | IFL Frequency Range |
|---|---|
| Ku-band VSAT (standard) | 950–1,450 MHz (low band) or 950–2,150 MHz (wideband) |
| Ku-band VSAT (wideband LNB) | 950–2,150 MHz |
| Ka-band VSAT | 950–2,150 MHz |
| C-band VSAT | 950–1,750 MHz (typical) |
Impedance and Connectors
All IFL cables are 50Ω. Do not use 75Ω cable (standard satellite TV cable) for IFL runs — the impedance mismatch introduces reflections and degrades signal quality. Both ends terminate in N-type connectors, the standard for VSAT IFL work. See the N-Type vs SMA vs BNC connector guide for a full comparison.
Cable Types for IFL Runs
The Times Microwave LMR series is the industry standard for VSAT IFL installations.
| Cable | OD | Loss at 1 GHz | Loss at 2 GHz | DC Resistance (Ω/100m) | Typical Use |
|---|---|---|---|---|---|
| LMR-240 | 7.3 mm | 10.2 dB/100m | 14.8 dB/100m | 3.0 | Short jumpers, tight spaces |
| LMR-400 | 10.8 mm | 5.6 dB/100m | 8.0 dB/100m | 1.4 | Standard IFL runs up to 75m |
| LMR-600 | 15.8 mm | 3.6 dB/100m | 5.2 dB/100m | 0.9 | Long runs 75–130m |
| LMR-900 | 22.9 mm | 2.4 dB/100m | 3.5 dB/100m | 0.6 | Very long runs 130m+ |
Attenuation at 2 GHz per 100m — visual comparison:
For a direct cable comparison, see LMR-400 vs LMR-600: Which Should You Choose?
IFL Signal Loss: How to Calculate Your Run
Attenuation accumulates with distance. Every metre of cable, every connector, and every in-line component adds insertion loss.
Total loss (dB) = Cable loss (dB/m) × Run length (m) + Connector loss × Count + In-line component losses
A good N-type connector pair adds approximately 0.1–0.2 dB. Surge arrestors add 0.3–0.5 dB each.
LMR-400 Loss Reference
| Run Length | Loss at 1 GHz | Loss at 1.5 GHz | Loss at 2 GHz |
|---|---|---|---|
| 10 m | 0.56 dB | 0.69 dB | 0.80 dB |
| 20 m | 1.12 dB | 1.38 dB | 1.60 dB |
| 30 m | 1.68 dB | 2.07 dB | 2.40 dB |
| 40 m | 2.24 dB | 2.76 dB | 3.20 dB |
| 50 m | 2.80 dB | 3.45 dB | 4.00 dB |
| 60 m | 3.36 dB | 4.14 dB | 4.80 dB |
| 75 m | 4.20 dB | 5.18 dB | 6.00 dB |
| 100 m | 5.60 dB | 6.90 dB | 8.00 dB |
LMR-600 Loss Reference
| Run Length | Loss at 1 GHz | Loss at 1.5 GHz | Loss at 2 GHz |
|---|---|---|---|
| 30 m | 1.08 dB | 1.33 dB | 1.56 dB |
| 50 m | 1.80 dB | 2.22 dB | 2.60 dB |
| 75 m | 2.70 dB | 3.33 dB | 3.90 dB |
| 100 m | 3.60 dB | 4.44 dB | 5.20 dB |
| 150 m | 5.40 dB | 6.66 dB | 7.80 dB |
Cable loss at 2 GHz: 4.80 dB
Connectors (4 × 0.15 dB): 0.60 dB
Surge arrestor: 0.40 dB
Total IFL loss: 5.80 dB
Maximum IFL Run Lengths
| Cable Type | Practical Maximum | Notes |
|---|---|---|
| LMR-240 | 25–30 m | Short jumpers only |
| LMR-400 | 50–75 m | Standard for most commercial sites |
| LMR-600 | 100–130 m | Longer buildings, rooftop-to-basement |
| LMR-900 | 150–200 m | Large campus or remote antenna |
For runs beyond 75m on LMR-400, move to LMR-600. For runs exceeding 150m, consider relocating the modem closer to the dish or using a fibre optic IFL.
DC Power and Voltage Drop on Long Runs
The IFL cable carries DC power from the modem to the LNB (typically 13V or 18V at up to 500 mA). LMR-400 centre conductor resistance: ~1.4 Ω per 100m. At 100m with 400 mA LNB current, voltage drop ≈ 0.56V — within tolerance for most systems. At 200m+ on LMR-400, verify LNB minimum operating voltage against actual delivered voltage before commissioning.
Weatherproofing the ODU Connection
Moisture ingress at the N-type connector where the IFL meets the LNB or BUC is one of the most common causes of IFL degradation in the GCC. Weatherproof every outdoor connection on the day of installation.
- Terminate with an N-type crimp connector — see the LMR connector crimping guide for strip dimensions and tooling.
- Mate the connector — N-type hex nut finger-tight plus a quarter turn with a 7/16″ spanner.
- Wrap with self-amalgamating tape, starting below the connector body, 50% overlap, two full passes minimum.
- Overwrap with PVC electrical tape for UV protection.
- Secure the cable to the mount at regular intervals to prevent wind stress on the connector.
Common IFL Installation Mistakes
| Mistake | Effect | Fix |
|---|---|---|
| Using 75Ω RG6 cable | Impedance mismatch, high attenuation, poor transmit performance | Use 50Ω LMR-series cable |
| Exceeding minimum bend radius | Kinked dielectric, local attenuation increase | Route through gentle curves; use conduit elbows |
| Unterminated cable ends during installation | Moisture ingress into dielectric | Cap unused ends with N-type terminator immediately |
| Outdoor connections not weatherproofed | Connector corrosion, rising insertion loss | Self-amalgamating tape every outdoor connection, same day |
| IFL run parallel to AC mains | RF interference pickup at L-band | Separate by 100mm minimum; use metal conduit |
Sourcing IFL Cable in the UAE and GCC
For professional-grade IFL installations — Times Microwave LMR-400, LMR-600, with matched N-type crimp connectors — source from a distributor carrying genuine Times Microwave product. Off-brand cable with inconsistent impedance control introduces return loss problems that are difficult to diagnose without a VNA.
Bravo Satcom carries LMR cable and RF connectors suited to VSAT IFL installations across the GCC.
Summary
The IFL cable is a critical and often underspecified component in VSAT installations. Use 50Ω LMR-series cable — LMR-400 for runs up to 75m, LMR-600 beyond that. Calculate your total IFL loss including connectors and in-line components, weatherproof every outdoor connection, and verify DC voltage delivery on long runs.
LMR Cable for VSAT — Stocked in Dubai
LMR-400, LMR-600, and matched N-type connectors available for immediate supply across the UAE and GCC.
View Cable Range →الكابل الرابط بين وحدة VSAT الخارجية وجهاز المودم يُعرف بكابل IFL — رابط التردد المتوسط (Intermediate Frequency Link). يحمل هذا الكابل إشارة القمر الصناعي بعد أن يخفّض LNB ترددها من نطاق Ku أو C إلى نطاق L-Band (950–2150 ميغاهرتز)، كما يحمل إشارة الإرسال الصاعدة من BUC قبل إرسالها.
يغطي هذا الدليل ماهية IFL، وكيفية اختيار الكابل المناسب، وطريقة حساب الخسارة، والأطوال القصوى لكل نوع كابل.
ما هو كابل IFL؟
IFL اختصار لـ Intermediate Frequency Link. وهو الكابل المحوري الذي يربط الوحدة الخارجية (ODU — الطبق الهوائي وتجميعة BUC وLNB) بالوحدة الداخلية (IDU — مودم VSAT أو الموجّه الفضائي).
طبق + BUC + LNB
نطاق L-Band
مودم VSAT
يحمل كابل IFL كلتا الإشارتين — استقبالاً نزولاً وإرسالاً صعوداً — عبر مسار محوري واحد، مع تيار التغذية المستمر (13 أو 18 فولت) ونبضة 22 كيلوهرتز للتحكم في استقطاب LNB.
مواصفات كابل IFL
| نوع المنظومة | نطاق تردد IFL |
|---|---|
| VSAT بنطاق Ku (قياسي) | 950–2,150 ميغاهرتز |
| VSAT بنطاق Ka | 950–2,150 ميغاهرتز |
| VSAT بنطاق C | 950–1,750 ميغاهرتز |
جميع كابلات IFL بممانعة 50 أوم وموصلات N-Type. لا تستخدم كابل 75 أوم (RG6) — عدم تطابق الممانعة يُدهور الإشارة خاصةً على جانب الإرسال.
سلسلة LMR من Times Microwave — المعيار القياسي
| الكابل | القطر الخارجي | عند 1 غيغاهرتز | عند 2 غيغاهرتز | الاستخدام |
|---|---|---|---|---|
| LMR-240 | 7.3 ملم | 10.2 ديسيبل/100م | 14.8 ديسيبل/100م | وصلات قصيرة داخلية |
| LMR-400 | 10.8 ملم | 5.6 ديسيبل/100م | 8.0 ديسيبل/100م | المعيار حتى 75م |
| LMR-600 | 15.8 ملم | 3.6 ديسيبل/100م | 5.2 ديسيبل/100م | مسارات 60–130م |
| LMR-900 | 22.9 ملم | 2.4 ديسيبل/100م | 3.5 ديسيبل/100م | مسارات 120م+ عالية الاستطاعة |
حساب خسارة إشارة IFL
موصل N-Type: ~0.15 ديسيبل | واقي الجهد الزائد: ~0.4 ديسيبل
جدول LMR-400
| طول المسار | 1 غيغاهرتز | 1.5 غيغاهرتز | 2 غيغاهرتز |
|---|---|---|---|
| 10م | 0.56 ديسيبل | 0.69 ديسيبل | 0.80 ديسيبل |
| 20م | 1.12 ديسيبل | 1.38 ديسيبل | 1.60 ديسيبل |
| 30م | 1.68 ديسيبل | 2.07 ديسيبل | 2.40 ديسيبل |
| 50م | 2.80 ديسيبل | 3.45 ديسيبل | 4.00 ديسيبل |
| 75م | 4.20 ديسيبل | 5.18 ديسيبل | 6.00 ديسيبل |
| 100م | 5.60 ديسيبل | 6.90 ديسيبل | 8.00 ديسيبل |
جدول LMR-600
| طول المسار | 1 غيغاهرتز | 1.5 غيغاهرتز | 2 غيغاهرتز |
|---|---|---|---|
| 30م | 1.08 ديسيبل | 1.33 ديسيبل | 1.56 ديسيبل |
| 50م | 1.80 ديسيبل | 2.22 ديسيبل | 2.60 ديسيبل |
| 75م | 2.70 ديسيبل | 3.33 ديسيبل | 3.90 ديسيبل |
| 100م | 3.60 ديسيبل | 4.44 ديسيبل | 5.20 ديسيبل |
| 150م | 5.40 ديسيبل | 6.66 ديسيبل | 7.80 ديسيبل |
الأطوال القصوى لمسار IFL
| نوع الكابل | الحد العملي | ملاحظات |
|---|---|---|
| LMR-240 | 25–30م | وصلات قصيرة فقط |
| LMR-400 | 50–75م | معيار معظم المواقع التجارية |
| LMR-600 | 100–130م | مباني كبيرة، من السطح إلى القبو |
| LMR-900 | 150–200م | منشآت كبيرة أو هوائيات بعيدة |
حماية الوصلة الخارجية من العوامل الجوية
- ثبّت كابل IFL بموصل N-Type مناسب باستخدام الأداة والقالب الصحيحَين لقطر كابلك.
- أحكم ربط الموصل يدوياً ثم ربع لفة إضافية بمفتاح 7/16 بوصة.
- لفّ الوصلة بشريط لاصق ذاتي الاندماج بدءاً من أسفل الموصل وصولاً فوقه وعودةً — مرتان كاملتان على الأقل.
- اختيارياً، أضف شريط PVC كهربائي للحماية من الأشعة فوق البنفسجية.
- ثبّت الكابل على العمود/الحامل لمنع إجهاد الرياح على الموصل.
خلاصة
كابل IFL مكوّن حيوي كثيراً ما يُهمَل. استخدم كابل LMR قياسي 50 أوم — LMR-400 للمسارات حتى 75م، وLMR-600 ما بعد ذلك. احسب الخسارة الكلية مع الموصلات، احمِ كل وصلة خارجية، وتحقق من جهد التيار المستمر في المسارات الطويلة.
مصادر الكابلات والموصلات في الإمارات والخليج
تستوك برافو ساتكوم كابلات RF وموصلات N-Type المناسبة لتركيبات IFL للـ VSAT في أنحاء الخليج.
تواصل: sales@bravosatcom.com | 971+ 55 541 5892