Product Classification:
- Product Type: Wireless and radiating connector
- Product Brand: HELIAX® | Positive Stop™
- Product Series: LDF4-50A
- Ordering Note: CommScope® standard product (Global)
General Specifications:
- Body Style: Straight
- Cable Family: AL4-50
- Harmonized System (HS) Code: 85366910 (Coaxial cable and other coaxial electric conductors)
- Inner Contact Attachment Method: Captivated
- Inner Contact Plating: Silver
- Interface: N Male
- Mounting Angle: Straight
- Outer Contact Attachment Method: Ring-flare
- Outer Contact Plating: Trimetal
Dimensions:
- Length: 76.71 mm | 3.02 in
- Diameter: 22.35 mm | 0.88 in
- Nominal Size: 1/2 in
3rd Order IMD (Intermodulation Distortion) at Frequency:
- -116 dBm @ 910 MHz
- Test Method: Two +43 dBm carriers
Insertion Loss Coefficient, typical:
- 0.05
Average Power at Frequency:
- 0.6 kW @ 900 MHz
Cable Impedance:
- 50 ohms
Connector Impedance:
- 50 ohms
DC Test Voltage:
- 2000 V
Inner Contact Resistance, maximum:
- 2 mOhm
Insulation Resistance, minimum:
- 5000 MOhm
Operating Frequency Band:
- 0 – 8800 MHz
Outer Contact Resistance, maximum:
- 0.3 mOhm
Peak Power, maximum:
- 10 kW
RF Operating Voltage, maximum (vrms):
- 707 V
Shielding Effectiveness:
- -130 dB
VSWR/Return Loss:
- Frequency Band: 45–1000 MHz
- VSWR: 1.023
- Return Loss (dB): 38.89
Mechanical Specifications:
- Attachment Durability: 25 cycles
- Connector Retention Tensile Force: 889.64 N | 200 lbf
- Connector Retention Torque: 5.42 N-m | 47.998 in lb
- Coupling Nut Proof Torque: 4.52 N-m | 39.997 in lb
- Coupling Nut Retention Force: 444.82 N | 100 lbf
- Coupling Nut Retention Force Method: MIL-C-39012C-3.25, 4.6.22
- Insertion Force: 66.72 N | 15 lbf
- Insertion Force Method: MIL-C-39012C-3.12, 4.6.9
- Interface Durability: 500 cycles
- Interface Durability Method: IEC 61169-16:9.5
- Mechanical Shock Test Method: MIL-STD-202, Method 213, Test Condition I
Environmental Specifications:
- Operating Temperature: -55 °C to +85 °C (-67 °F to +185 °F)
- Storage Temperature: -55 °C to +85 °C (-67 °F to +185 °F)
- Corrosion Test Method: MIL-STD-1344A, Method 1001.1, Test Condition A
- Immersion Depth: 1 m
- Immersion Test Mating: Unmated
- Immersion Test Method: IEC 60529:2001, IP68
- Moisture Resistance Test Method: MIL-STD-202F, Method 106F
- Thermal Shock Test Method: MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C
- Vibration Test Method: IEC 60068-2-6
- Water Jetting Test Mating: Unmated
- Water Jetting Test Method: IEC 60529:2001, IP66
#L4TNM‐PSA supplier in dubai, #commscope L4TNM‐PSA supplier in dubai, #CNT400 N Male supplier in dubai, #CNT 400 Connector supplier in dubai, #L4TNM‐PSA connector supplier in dubai, #L4TNM‐PSA supplier in Abu Dhabi, #commscope L4TNM‐PSA supplier in Abu Dhabi, #CNT400 N Male supplier in Abu Dhabi, #CNT 400 Connector supplier in Abu Dhabi, #L4TNM‐PSA price saudi arabia, #commscope L4TNM‐PSA price saudi arabia, #CNT400 N Male price saudi arabia, #CNT 400 Connector price saudi arabia, #L4TNM‐PSA connector price saudi arabia,